Add to Cart
ABB Module 07PS62R2 ABB 07PS62 R2 ABB 07PS62-R2 Program Memory Module affordable price
Product Description:
The input impedance is ca. 330 Ω. The current input has a self-protecting mechanism. If the input current gets too high, the shunt is switched off and the value for range overflow is generated. About every second, the unit tries to switch on the shunt again. In this way the correct measurement
will succeed after the current has reached a normal value again. The trigger of the self-protecting mechanism is displayed by the red LED Ovl as long as the overload is present. Inthe PLC system an error message is then stored (FK4, error number 4). The following figure shows the connection of a 3-wire sensor powered by 24 V DC and of a 2-pole sensor powered electrically isolated. Both sensors work as active current sources 0...20 mA.
Related Product Recommendation:
GJV3074322R302 | BRC-100 P-HC-BRC-10000000 | 07ZE63R302 GJV3074323R302 |
GJV3074323R302 | BRC100 BRC-100 P-HC-BRC-10000000 | 086363-002 OSPS2 |
07ZE85R1 GJR5219400R0001/9075 | BRC300 PHCBRC30000000 | 1700RZ10005C |
GJR5231800R101 | C100/0100/STD | 1SAR330020R0000 |
GJV3074356R1 | C1900/0263/0260A C1900/0263 | 200-CICN 200-CIE |
GJR5215300R2 | C1900/0363 C1900/0363/0360A | 2012AZ10101B |
GJV3074305R1 | C300/0010/STD | 35AE92A ER0002081060005 |
HETN100004P1 | CI520V1 3BSE012869R1 | 3ASC25H705/7 |
XE08B5 XE08B5-d04 | CI522 3BSE012790R1 | 3ASU21C110 LU6278 DCU30/7 |
ICMK14F1 ICMK14F1-K10.0 | CI522A 3BSE018283R1 | 3AUA489002B4562 |
SACEPR120/B | CI526 3BSE006085R1 | 3BHE022291R0101 PCD230A PC D230 A |
HETN200007P1 | CI531 3BSE003825R1 | 3BHE023784R2530 PP D113 B01-25-111000 |
FPR3700001R0001 | CI532V01 3BSE003826R1 | 3BHE024577R0101 PP C907 BE |
HESG330065R0001 | CI532V02 3BSE003827R1 | 3BSE001245R1 3BSC640008R1 |
HEDT300841R20 ED1310cR20 | CI532V02 3BSE003827R1 | 3BSE003879R1 |
HEDT300383R1 | 07KT93 GJR5251300R0171 | 3BSE011316R1 SDCS-PIN-52 |
GJR2343800R2 | 07KT94 GJR5252100R0101 | 3HAC14550-4 |
HEDT401049P2 | 07KT94 GJR5252100R2261 | 3HAC14551-2 |
HEDT300843R1 | 07KT97 GJR5253000R0270 | 3HAC17484-8 |
HEDT300371R1 | 07KT97 WT97 | 3HAC17484-9 |
HEDT401033P2 | 07KT98 GJR5253100R0270 | 3HNE00313-1 |
HEDT300340R1 | 07KT98 WT98 | 3HNM09846-1 |
HEDT300379R1 | 07KT98 GJR5253100R0270 | 3HNP04014-1 |
HEDT300379R1 | 07KT98 WT98 | 424K1105 |
HEDT300379R1 | 07MK92 GATS110098R0161 | 6638910B1 638910B1PS0084 |
HESG330057R1 | 07MK92 GJR5253300R1161 | 7944831D |
HESG330057R1 | 07NG61R1 GJV3074311R1 | 89AR30 |
HESG330086R1 | 07NG63R1 GJV3074313R1 | A8PU05ABFW02 |
HESG330038R1 | 07PS62R2 GJV3074332R2 | AI610 3BHT300000R1 |
HEDT300867R1 | AI810 3BSE008516R1 | AI625 3BHT300036R1 |
HESG330057R1 | AI830A 3BSE040662R1 | AI630 3BHT300011R1 |
Product's Character:
It has to be taken into consideration, that in this application the M terminal of the basic unit 07 KT 94 is
the reference potential. AGND1 is not dimensioned for carrying the sum of the sensor currents. The value of the range underflow is stored. If the ope circuit monitoring is configured, the open-circuit event is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9). The following figure shows the connection of 2-pole passive- type analog sensors 4...20 mA. If the analog current sensors 4...20 mA are powered from a separate power supply unit, the reference potentials 0V (of the separate power supply unit and the power supply unit for the 07 KT 94) must be interconnected to each other.In the above example, the AGND terminal remains
unused.
FPR3600228R0204 07KT31 07KT31 Central Processing Unit-120 VAC ABB
FPR3600228R0206 07KT31 07KT31Central Processing Unit - 230 VAC ABB
FPR3600228R1202 07KT31 07KT31 Central Unit - 30 Series- 24 VDC ABB
FSCA-01 Field Kit ABB
GAT 542989R0001 DKR-E 0601 ABB Axodym Power Supply ABB
GAT 543152R0001 DKRB 6/26 Power Supply/Servo Drive Case Unit ABB
GATS 1100 92 R0001 MT-60 MT-60 Operator Panel ABB
GATS110091R0001 MT-40 MT-40 Operator Panel ABB
GATS110091R0201 MT-40 MT40 Operator Panel ABB
GATS110091R0401 MT-40 MT-40 Operator Panel ABB
GATS110092R0401 MT60 MT60 Text Display ABB
GATS110092R0501 MT60 MT60 Text Display ABB
GATS110112R0001 07KP96 PDnet Coupler Module ABB
GATS110112R0002 07KP96 PDnet Coupler Module ABB
GATS110112R0003 07KP96 PDnet Coupler Module ABB
GATS110112R0011 07KP96 PDnet Coupler Module ABB
GATS110112R0012 07KP96 PDnet Coupler Module ABB
GATS110112R0013 07KP96 PDnet Coupler Module ABB
GATS110143R0002 07MK62 07MK62 - RS232 Communications Module ABB
GATS111100R0001 MT30 MT30 Text Display ABB
GHS2101945R0002 S2 ABB Label Holders ABB
GHS2701916R0001 S2-H11 ABB Module ABB
GJR4500400R1 35 NE 90, 35NE90 35 NE 90 Power Supply Unit ABB
GJR5136400R0001 35 GS 91; 35 GS 91C; 35 GS 91B 35 GS 91 Card File Rack ABB
GJR5136500R0001 35 GS 91 35 GS 91 Rack - 17 Slot ABB
GJR5137200R0005 35AE92 4 Channel Axis Module ABB
GJR5137400R0002 35 DS 91 35 DS 91 Interface Module ABB
GJR5142600R0001 35 EB 91 35EB91 I/O CARD ABB
GJR5142800R0001 35 AB 94B, 35 AB 94 35 AB 94 Digital Output Module ABB
GJR5143000R0002 35 AA 92C-E 35 AA 92 Analog Output Module ABB
GJR5143100R0001 35 EK 90 35 EK 90 Bus Coupler Unit ABB
GJR5143200R0001 35 EK 91 35 EK 91 Bus Coupler Unit ABB
The use of the product:
1.We keep more than 10 thousands Transistors in warehouse, it could cut lead time of most items.
2. new and original
3.1 year warranty
Our advantages:
1.emission reduction
2.Experienced technichal support team.
3.Avoid unplanned downtime
1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem, please contact with us,we'll provide suggestion from our engineer to help you solve problem.
3. Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1 piece .
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )